- P2 — The self-test accepts timeouts as proof that archive limits work. scanner-selftest:104
The classifier accepts Heuristics.Limits.Exceeded.MaxScanTime FOUND as a successful limit result. That proves only that scanning timed out, not that the deterministic archive limits prevented silent truncation. A regressed engine can therefore pass during transient load and later answer OK when that load subsides. ClamAV generates this reply specifically on timeout. ClamAV 1.4.3 source
The substring match also accepts Win.Heuristics.Limits.Exceeded.Fake FOUND. Both misclassifications were reproduced using the actual classifier.
Fix: Parse the signature and accept only the expected deterministic limit names. Treat MaxScanTime as failure or retry it within a bounded policy; reject lookalikes. Add regression cases for both.
- P3 — A logging failure bypasses the required FAILED marker. scanner-init.sh.tftpl:15
If tee /dev/console fails inside say(), set -e terminates the script without invoking the non-inherited ERR trap. Simulating that failure with the actual function definitions produced exit status 1 but no SCANNER-HOST FAILED: marker. The prescribed serial-output polling can consequently receive neither terminal marker.
Fix: Handle logging failures explicitly, or inherit the trap with set -E and make fail() emit its marker through a fallback that does not depend on successful serial-console logging.
Reviewed 092c5a85; no files changed. Shell syntax, OpenTofu formatting and diff checks passed. Go, provider-backed and live-box tests were not run.